Current Build
NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation 0..*
... extension ExtensionSlice: Unordered, Open by value:Observation.extension
... reportingPriority 0..1CodeableConceptObservation:hspcEstradiolMCncPtSerPlasQnHighsensitivityLabObs:reportingPriority
URL: http://hl7.org/fhir/hspc/StructureDefinition/reportingPriority
Binding: HSPC Reporiting Priority value set (preferred)
... deltaFlag 0..1CodeableConceptObservation:hspcEstradiolMCncPtSerPlasQnHighsensitivityLabObs:deltaFlag
URL: http://hl7.org/fhir/hspc/StructureDefinition/deltaFlag
... modifierExtension 0..1FocalSubjectObservation:hspcEstradiolMCncPtSerPlasQnHighsensitivityLabObs.modifierExtension:focalSubject
... identifier IdentifierSlice: Unordered, Open by value:Observation.identifier
... identifier 0..1IdentifierObservation:hspcEstradiolMCncPtSerPlasQnHighsensitivityLabObs:accessionNumber
... identifier 0..1IdentifierObservation:hspcEstradiolMCncPtSerPlasQnHighsensitivityLabObs:fillerOrderNumber
... identifier 0..1IdentifierObservation:hspcEstradiolMCncPtSerPlasQnHighsensitivityLabObs:placerOrderNumber
... code 1..1CodeableConceptObservation:hspcEstradiolMCncPtSerPlasQnHighsensitivityLabObs.key
Fixed Value: {"coding":[{"system":"http://loinc.org","code":"35384-7","display":"Estradiol (E2) [Mass/volume] in Serum or Plasma by High sensitivity method"}]}
... issued 0..1instantObservation:hspcEstradiolMCncPtSerPlasQnHighsensitivityLabObs.resultedDateTime
... performer Reference(Practitioner | Organization | Patient | RelatedPerson)Slice: Unordered, Open by value:Observation.performer
... performer 0..*Reference(http://hl7.org/fhir/hspc/StructureDefinition/practitioner)Observation:hspcEstradiolMCncPtSerPlasQnHighsensitivityLabObs:responsibleObserver
... performer 0..1Reference(http://hl7.org/fhir/hspc/StructureDefinition/organization)Observation:hspcEstradiolMCncPtSerPlasQnHighsensitivityLabObs:performingLaboratory
... performer 0..1Reference(http://hl7.org/fhir/hspc/StructureDefinition/practitioner)Observation:hspcEstradiolMCncPtSerPlasQnHighsensitivityLabObs:performingOrganizationMedicalDirector
... valueQuantity 0..1QuantityObservation:hspcEstradiolMCncPtSerPlasQnHighsensitivityLabObs.valueQuantity
.... system 0..1??Observation:hspcEstradiolMCncPtSerPlasQnHighsensitivityLabObs.valueQuantity.system
Fixed Value: http://unitsofmeasure.org
.... code 0..1??Observation:hspcEstradiolMCncPtSerPlasQnHighsensitivityLabObs.valueQuantity.code
Fixed Value: pg/mL
... interpretation 0..1CodeableConceptObservation:hspcEstradiolMCncPtSerPlasQnHighsensitivityLabObs.interpretation

doco Documentation for this format